Both Mirrors Do Not Operate
- Disconnect mirror control switch connector. Connect test light between Orange wire terminal of mirror control switch connector and ground.
- If test light does not come on, check Orange wire for an open or short to ground. If test light comes on, connect test light between Orange wire terminal and Black wire terminal of mirror control switch connector.
- If test light does not come on, check Black wire circuit for an open. If test light comes on, check mirror control switch connector. If connector is okay, replace mirror control switch.