HVAC Control Module Connector End View C1
HVAC Control Module C1
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit No. | Function |
| A1 | DK GRN | 1614 | Recirculation Door Control |
| A2 | DK BLU | 1646 | Right Air Temperature Door Position Signal |
| A3 | LT BLU | 733 | Left Air Temperature Door Position Signal |
| A4 | LT GRN/ BLK |
2276 | Defrost Door Position Signal |
| A5 | LT GRN | 2275 | Mode Door Position Signal |
| A6 | - | - | Not Used |
| A7 | BRN/WHT | 230 | Instrument Panel Lamps Dimming Control |
| A8 | BLK/WHT | 751 | Ground |
| A9 | GRY/BLK | 1596 | Coolant Bypass Solenoid Control (Body Type VIN 6) |
| A10 | YEL | 2277 | Not Used |
| A11 | - | - | Not Used |
| A12 | DK BLU | 204 | A/C Low Pressure Sensor Signal |
| B1 | WHT/BLK | 1236 | Right Air Temperature Door Control |
| B2 | DK BLU | 1199 | Left Air Temperature Door Control |
| B3 | TAN/BLK | 2274 | Defrost Door Control |
| B4 | TAN | 2273 | Mode Door Control |
| B5 | BRN | 341 | Ignition 3 Voltage |
| B6 | YEL | 1791 | Low Reference |
| B7 | ORN | 4340 | Battery Positive Voltage |
| B8 | LT BLU/ BLK |
1688 | 5 Volt Reference |
| B8 | - | - | Not Used |
| B9 | BLK | 2250 | Ground |
| B11 | WHT | 1038 | Class 2 Serial Data |
| B12 | LT GRN | 2278 | A/C Compressor Status Signal |
HVAC Control Module C1
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit No. | Function |
| A1 | DK GRN | 1614 | Recirculation Door Control |
| A2 | DK BLU | 1646 | Right Air Temperature Door Position Signal |
| A3 | LT BLU | 733 | Left Air Temperature Door Position Signal |
| A4 | LT GRN/BLK | 2276 | Defrost Door Position Signal |
| A5 | LT GRN | 2275 | Mode Door Position Signal |
| A6 | - | - | Not Used |
| A7 | BRN/WHT | 230 | Instrument Panel Lamps Dimming Control |
| A8 | BLK/WHT | 751 | Ground |
| A9 | GRY/BLK | 1596 | Coolant Bypass Solenoid Control (Body Type VIN 6) |
| A10 | YEL | 2277 | Auxiliary HVAC Enable Control |
| A11 | DK GRN | 71 | OFF Blower Motor Control |
| A12 | DK BLU | 204 | A/C Low Pressure Sensor Signal |
| B1 | WHT/BLK | 1236 | Right Air Temperature Door Control |
| B2 | DK BLU | 1199 | Left Air Temperature Door Control |
| B3 | TAN/BLK | 2274 | Defrost Door Control |
| B4 | TAN | 2273 | Mode Door Control |
| B5 | BRN | 341 | Ignition 3 Voltage |
| B6 | YEL | 1791 | Low Reference |
| B7 | ORN | 4340 | Battery Positive Voltage |
| B8 | LT BLU/BLK | 1688 | 5 Volt Reference |
| B9 | BLK | 2250 | Ground |
| B10 | - | - | Not Used |
| B11 | WHT | 1038 | HVAC Class 2 Serial Data |
| B12 | LT GRN | 2278 | A/C Compressor Status Signal |