July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!
Oxygen Sensor R & I: Installation
Coat threads of new sensor with nickel-based anti-seize compound. Do not use graphite or other compounds. Start sensor by hand, then tighten to 35 ft. lbs. (47 N.m). Install air cleaner and connect battery cable.