Scan Tool Data Definitions

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2002 GMC Yukon XL, 2002 GMC Yukon, 2002 Chevrolet Tahoe, 2002 Chevrolet Suburban, and 2002 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
HVAC - Primary ECC Data - Outside Air Temp

The scan tool displays -40 to +60°C (-40 to +140°F). The output of the ambient air temperature sensor.

HVAC - Primary ECC Data - Inside Air Temp

The scan tool displays -40 to +60°C (-40 to +140°F). The output of the inside air temperature sensor.

HVAC - Primary ECC Data - Upper Outlets Duct Temp

The scan tool displays -40 to +150°C (-40 to +300°F). The output of the upper outlets duct temperature sensor.

HVAC - Primary ECC Data -Lower Outlets Duct Temp

The scan tool displays -40 to +150°C (-40 to +300°F). The output of the lower outlets duct temperature sensor.

HVAC - Auxiliary ECC Data - Aux. Inside Air Temp

The scan tool displays -40 to +150°C (-40 to +300°F). The output of the Aux. inside air temperature sensor.

HVAC - Auxiliary ECC Data -Aux. Upper Outlet Temp

The scan tool displays -40 to +150°C (-40 to +300°F). The output of the Aux. Upper Outlet temperature sensor.

HVAC - Auxiliary ECC Data -Aux. Lower Outlet Temp

The scan tool displays -40 to +150°C (-40 to +300°F). The output of the Aux. Lower Outlet temperature sensor.

HVAC - Primary ECC Data - Solar Sensor

The scan tool displays 0-250 counts. The solar load output of the sunload sensor.

HVAC - Primary ECC Data - Blower Motor PWM Speed

The scan tool displays 0-98%.

HVAC -Auxiliary ECC Data -Auxiliary Blower Motor PWM

The scan tool displays 0-98%.

HVAC - Primary ECC Data - Mode Selection Position

The scan tool displays AUTO, Upper, Defog, Bi-Level, Heater or Defrost. The current operating mode of the HVAC system.

HVAC - Primary ECC Data - A/C Request

The scan tool displays Yes or No.

HVAC - Primary ECC Data - A/C LED On

The scan tool displays on or off.

HVAC - Primary ECC Data -Recirc LED

The scan tool displays on or off.

HVAC - Primary ECC Data -Outside Air LED

The scan tool displays on or off.

HVAC - Primary ECC Data -Rear Defog

The scan tool displays on or off.

HVAC -Primary ECC Data -Mode Door Actual

The scan tool displays 0-255 counts. The signal output from the feedback pot on the actuator.

HVAC -Primary ECC Data - Mode Door Commanded

The scan tool displays 0-255 counts. The desired position of the actuator.

HVAC -Primary ECC Data - Mode Door Max. Position

The scan tool displays 0-255 counts. The maximum travel range when driven to the door stop during a recalibration.

HVAC -Primary ECC Data - Mode Door Min. Position

The scan tool displays 0-255 counts. The minimum travel range when driven to the door stop during a recalibration.

HVAC -Auxiliary ECC Data -Aux. Mode Door Actual

The scan tool displays 0-255 counts. The signal output from the feedback pot on the actuator.

HVAC -Auxiliary ECC Data -Aux. Mode Door Commanded

The scan tool displays 0-255 counts. The desired position of the actuator.

HVAC -Auxiliary ECC Data -Aux. Mode Door Max. Position

The scan tool displays 0-255 counts. The maximum travel range when driven to the door stop during a recalibration.

HVAC -Auxiliary ECC Data -Aux. Mode Door Min. Position

The scan tool displays 0-255 counts. The minimum travel range when driven to the door stop during a recalibration.

HVAC - Primary ECC Data- Air Inlet Door Actual

The scan tool displays 0-255 counts. The signal output from the feedback pot on the actuator.

HVAC -Primary ECC Data - Air Inlet Door Commanded

The scan tool displays 0-255 counts. The desired position of the actuator.

HVAC -Primary ECC Data - Air Inlet Door Max.

The scan tool displays 0-255 counts. The maximum travel range when driven to the door stop during a recalibration.

HVAC -Primary ECC Data - Air Inlet Door Min.

The scan tool displays 0-255 counts. The minimum travel range when driven to the door stop during a recalibration.

HVAC - Primary ECC Data -Air Mix Door Actual

The scan tool displays 0-255 counts. The signal output from the feedback pot on the actuator.

HVAC - Primary ECC Data -Air Mix Door Commanded

The scan tool displays 0-255 counts. The desired position of the actuator.

HVAC - Primary ECC Data -Air Mix Door Max. Position

The scan tool displays 0-255 counts. The maximum travel range when driven to the door stop during a recalibration.

HVAC - Primary ECC Data -Air Mix Door Min. Position

The scan tool displays 0-255 counts. The minimum travel range when driven to the door stop during a recalibration.

HVAC -Auxiliary ECC Data -Aux. Mix Door Actual

The scan tool displays 0-255 counts. The signal output from the feedback pot on the actuator.

HVAC -Auxiliary ECC Data -Aux. Mix Door Commanded

The scan tool displays 0-255 counts. The desired position of the actuator.

HVAC -Auxiliary ECC Data -Aux. Mix Door Max. Position

The scan tool displays 0-255 counts. The maximum travel range when driven to the door stop during a recalibration.

HVAC -Auxiliary ECC Data -Aux. Mix Door Min. Position

The scan tool displays 0-255 counts. The minimum travel range when driven to the door stop during a recalibration.

HVAC - Miscellaneous Tests - Instant OAT Update

The scan tool displays Commanded State: None or On. Updates the ECC outside air temperature input to the current raw value.

HVAC - Miscellaneous Tests - Blower Motor

The scan tool displays Commanded State: None, Off or On. This function allows you to command the blower motor to its maximum (100%) or minimum (0%) speeds.

HVAC -Special Functions-Set Up New HVAC

This function has the ECC relearn a new heater and A/C control.

PCM - A/C Information - A/C Clutch Feedback Signal

The scan tool displays On or Off. On is displayed when the PCM has energized the A/C clutch relay.

PCM - Engine Data 1 - ECT

The scan tool displays -40 to +215°C (-40 to +420°F). The output of the engine coolant temperature sensor.

PCM - Engine Data 2 - ECT

The scan tool displays -40 to +215°C (-40 to +420°F). The output of the engine coolant temperature sensor.

PCM - Engine Data 2 - Commanded A/C

The scan tool displays On or Off. On is displayed when the PCM has energized the A/C clutch relay.

PCM - Engine Data 2 - A/C Compressor Cycling Switch

The scan tool displays Normal and Low Pressure. The output of the A/C pressure sensor.

PCM - Engine Data 2 - A/C Request Signal

The scan tool displays Yes or No. Yes is displayed when the HVAC control module is requesting the PCM to turn on the compressor clutch.

PCM - Engine Data 2 - A/C High Pressure Recirculation Switch

The scan tool displays OK or Low Pressure. Displays the output of the High Pressure Recirculation Switch.