Installation Procedure
WARNING: This page is about a different car, the 2004 Chevrolet Monte Carlo and 2004 Chevrolet Impala. However, it is still accessible from the selected car via links, so may be relevant.
IMPORTANT:
DO NOT apply thread sealant to the sensor threads. The sensor threads are coated at the factory. Applying additional sealant affects the sensors ability to detect detonation.
- Install the knock sensor.
Tighten: Tighten the knock sensor to 19 N.m (14 lb ft).
- Connect the knock sensor wiring harness electrical connector.
- Lower the vehicle.
NOTE:
Refer to Fastener Notice in Cautions and Notices.