Installation Procedure
- Align the BCM (1) to the bracket, making sure the retaining tabs are correctly located.
- Install the screw (2) attaching the BCM (2) to the bracket.
Tighten: Tighten the screw to 2 N.m (18 lb in).
- Connect the 4 BCM electrical connectors.
- Install the right closeout insulator/trim panel. Refer to Closeout/Insulator Panel Replacement - Right in Instrument Panel, Gages and Console.
- Perform the new BCM setup. Refer to Body Control Module (BCM) Programming/RPO Configuration in Computer/Integrating Systems.
- Program the transmitters. Refer to Transmitter Programming in Keyless Entry.