Installation Procedure
- Install the brake pressure modulator assembly to the bracket. Secure with the 2 nuts.
Tighten: Tighten the brake modulator assembly nuts to 6 N.m (53 lb in).
- Install the brake pressure modulator assembly and bracket. Secure with the nut (1).
Tighten: Tighten the brake modulator bracket nut to 20 N.m (15 lb ft).
- Install the 2 bolts (2) to the brake pressure modulator bracket (3).
Tighten: Tighten the brake modulator bracket bolts to 20 N.m (15 lb ft).
- Remove the plugs from the brake pipes and connect the brake pipes to the brake modulator assembly (1).
Tighten: Tighten the brake pipe fittings nuts to 15 N.m (11 lb ft).
- Connect the EBCM electrical connector (2).
- Secure the EBCM electrical connector lock lever (1).
- Bleed the brake system. Refer to Hydraulic Brake System Bleeding in Hydraulic Brakes.
- Using the scan tool, perform the yaw rate sensor zero point calibration under the special functions menu.
- Perform the Diagnostic System Check - Vehicle in Vehicle DTC Information.
NOTE:
Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.