Brake Pressure Modulator Valve Replacement
Brake Pressure Modulator Valve Replacement
| Callout | Component Name |
|---|---|
|
CAUTION:
Remove all the air from the hydraulic brake system anytime the hydraulic brake system is opened for repair. The entire bleeding procedure must be followed. Failure to remove all the air in the hydraulic brake system will result in reduced braking performance and possible personal injury.
CAUTION:
Refer to Brake Fluid Irritant Caution
.
NOTE:
Always connect or disconnect the wiring harness connector from the EBCM/EBTCM with the ignition switch in the OFF position. Failure to observe this precaution could result in damage to the EBCM/EBTCM.
NOTE:
Refer to Brake Fluid Effects on Paint and Electrical Components Notice
.
NOTE:
Refer to Fastener Notice
. Fastener Tightening Specifications:
Refer to Fastener Tightening Specifications .Preliminary Procedure
|
|
| 1 | Fittings, Brake Pressure Modulator Valve (Qty: 4) Tip:
Tighten: 19 N.m (14 lb ft) |
| 2 | Fittings, Brake Pressure Modulator Valve (Qty: 2) Tip:
Tighten: 19 N.m (14 lb ft) |
| 3 | Connector, BPMV Electrical |
| 4 | Bolt, BPMV to Mounting Bracket Tighten: 5.6 N.m (50 lb in) |
| 5 | Insulator, BPMV Mounting Bracket Tip: Inspect both upper and lower insulators for excessive wear and/or damage. Replace the insulators if necessary. |
| 6 | Bolt, BPVM Mounting (Qty: 4) Tip: Tighten the bolts in a criss-cross pattern. Tighten: 4.5 N.m (40 lb in) |
| 7 | Bolt, Brake Pressure Modulator Valve-to-Bracket Tighten: 5.6 N.m (50 lb in) |
| 8 | Module, Electronic Brake Control Module Tip:
|