Scan Tool Output Controls
LZ4, LZ9 Engine Control Module (ECM) Scan Tool Output
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| GEN L-Terminal | ECM, Special Functions, Output Control | The engine control module (ECM) commands the generator OFF when off is selected. The generator will then stop generating an output voltage. |
| Malfunction Indicator Lamp | ECM, Special Functions, Output Control | The instrument panel cluster (IPC) illuminates the malfunction indicator lamp (MIL) to test for an inoperative indicator. |
| Starter Relay | ECM, Special Functions, Output Control | The ECM commands the starter relay ON and OFF. |
LY7 Engine Control Module (ECM) Scan Tool Output
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| GEN L-Terminal | ECM, Special Functions, Output Control | The engine control module (ECM) commands the generator OFF when off is selected. The generator will then stop generating an output voltage. |
| Malfunction Indicator Lamp | ECM, Special Functions, Output Control | The instrument panel cluster (IPC) illuminates the malfunction indicator lamp (MIL) to test for an inoperative indicator. |
Instrument Panel Cluster (IPC) Scan Tool Output
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| Segment Check | IPC, Special Functions | The instrument panel cluster (IPC) illuminates all of the indicators for 7 seconds when On is selected. |