Circuit/System Testing
- Ignition OFF, disconnect the CMP actuator solenoid harness connector at the CMP actuator solenoid.
- Test for less than 5 ohms between the low reference circuit terminal B and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance.
- Verify that a test lamp does not illuminate between the low reference circuit terminal B and the control circuit terminal A.
- If the test lamp illuminates, test the control circuit for short to voltage. If the circuit tests normal, replace the ECM.
- Remove the test lamp.
- Command the CMP Actuator Sol. ON with a scan tool. Verify the scan tool CMP Sol Ckt Short Gnd Test status is OK.
- If not the specified value, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM.
- Install a 3amp fused jumper wire between the control circuit terminal A and the low reference circuit terminal B. Command the CMP Actuator Sol. ON with a scan tool. Verify the scan tool CMP Sol Ckt Short Gnd Test status is Fault.
- If not the specified value, test the control circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the CMP actuator solenoid.