Installation Procedure
- Install the 2 ECM brackets onto the ECM with the 4 screws (1, 2, 3, 4) and tighten to 3.2 N.m (28 lb in).
- Install the ECM with the 3 bolts (1, 2, 3) and tighten to 8.0 N.m (71 lb in).
- Connect the 2 ECM connectors and lower the 2 levers.
- Install the wire harness clamp (1).
- Install air cleaner assembly with hose. Refer to Air Cleaner Element Replacement .
- Connect cable to negative battery terminal.
- Perform the REGISTRATION (VIN registration) when replacing the ECM. Refer to Control Module References .
CAUTION:
Refer to Fastener Caution
.