Right Rear Speed Sensor (Internal Resistance)
- Press "HR" button. Digital display should read between 800-1800 ohms. If readout is okay, go to PROGRAM SWITCH POSITION 11 . If not, go to step 2).
- Check internal resistance and continuity between terminals No. 24 and 26 of disconnected control unit plug. Check plug connection. If not okay, replace speed sensor.