Evaporation System Pressure Test
CAUTION:
Use adequate ventilation. Do not smoke when pressure testing fuel evaporation system.
- Remove vent hose leading to fuel tank from charcoal canister. Using a "T" fitting, connect Saab APC Boost Pressure Gauge (83-93-514) and hand pump type coolant pressure tester to fuel tank vent hose.NOTE: Damage to fuel pump and mount, and tank grommets may occur if system is pressurized above 3 psi (.21 kg/cm2 ).
- Slowly pump air into hose until pressure reaches 3 psi (.21 kg/cm2 ) maximum. Maintain 3 psi (.21 kg/cm2 ) maximum on system for at least 5 minutes.
- Using soap water solution or HC meter, test for leakage at fuel filler cap and neck, fuel pump, hoses, connections, grommets, and fuel level sending unit.
- Tighten or replace any leaking component. Retest system. If new tank grommets leak during retest, seal them with Saab Special Sealant (30-21-250).