Programming Using Scan Tool
- Access PROGRAMMING menu on scan tool. Under DISABLE AUTOMATIC RECIRCULATION - YES/NO function, select NO. If NO is selected, manual or automatic air recirculation can be selected. If YES is selected, then air recirculation can only be selected manually.
- Under CIRCULATION PUMP - YES/NO function, select YES if vehicle is equipped with a coolant circulation pump. If vehicle is not equipped with a coolant circulation pump, select NO. If YES is selected and vehicle is not equipped with a circulation pump, an ACC control panel DTC 19 will be displayed on right side of control panel. If this occurs, select NO during ACC control module programming.
- Under CALIBRATION FOR CLIMATE ZONE - WARM CLIMATE/COLD CLIMATE function, make the selection most appropriate for climate region. Programming for climate zone specifies direction mixed-air flap is moved during ACC control module calibration. For WARM CLIMATE, calibration is toward maximum cold. For COLD CLIMATE, calibration is toward maximum heat. This function ensures that mixed-air flap does not leak when in position used most often for selected climate zone.