LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Saab >> 2009 >> 9-7X 5.3i >> Repair and Diagnosis >> General Information >> OEM General Information >> Vehicle Diagnostic Information >> Specifications >> Generator Battery Control Module Scan Tool Information
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Generator Battery Control Module Scan Tool Information

Generator Battery Control Module (GBCM)

Parameter System State Expected Value Description
Operating Conditions:  Ignition ON/Engine OFF
Battery Voltage Signal - 12.3 V The scan tool displays 0-20 volts. The scan tool displays the voltage as received by the module.
Generator L Terminal Signal Command - 0 Percent The scan tool displays On/Off. The scan tool displays Off until the engine is running, at which time it will display On.
Regulated Voltage Control Current Sensor - Varies The scan tool displays Amps. This controls how much current is going to or from the negative battery cable.
Running State of Charge - Varies The scan tool displays percent. This calculates the battery's state of charge based on current and voltage over a long period of time.
Generator Battery Control Module Output Controls

Output Control Description