Engine RPM Approximate AMP Output Generator Inlet Air Temp
650
650
28 - 36
16 - 24
27° C (81° F)
105° C (221° F)
875
875
58 - 66
39 -47
27° C (81° F)
105° C (221° F)
1000
1000
64 - 72
46 - 54
27° C (81° F)
105° C (221° F)
1500
1500
80 - 88
58 - 66
27° C (81° F)
105° C (221° F)
2000
2000
87 - 95
68 - 76
27° C (81° F)
105° C (221° F)