Mode 6 - L - Series W/V6: 2004-05
Mode $06 Data Definitions For L-Series W/V6
| Test ID (hex) | Type of Test Limit (see footnote on last page) and Comp ID (hex) | Description | Decimal Range | Hex Range |
|---|---|---|---|---|
| Enhanced Evaporative Emission System Monitor | ||||
| 05 | 01 | Evaporative Emission System Purge Valve Flow Monitor | 0 to 2 | 00 to 02 |
| 06 | 01 | Evaporative Emission System - Gross Leak Monitor | 0 to 2 | 00 to 02 |
| 07 | 01 | Evaporative Emission System - 0.020" Leak Monitor Factor | 0 to 1 factor | 0000 to 7FFF |
| Catalyst Efficiency Monitor | ||||
| 01 | 05 | Catalyst Oxygen Storage Factor - Bank 1 | 0 to 0.9961 factor | 00 to FF |
| 01 | 06 | Catalyst Oxygen Storage Factor - Bank 2 | 0 to 0.9961 factor | 00 to FF |
| Thermostat Monitoring | ||||
| 09 | 0A | Thermostat Monitoring - difference - Model versus Actual | 0 to 191,25 °C | 00 to FF |
| footnote: bit 7: Most significant bit indicates type of test limit, where: 0 - test limit is maximum value - test fails if test value is greater than this value 1 - test limit is minimum value - test fails if test value is less than this value If the test result should be within a range of values, two messages will be returned, one with the maximum value and one with the minimum value. bit 6 - bit 0 Component ID - manufacturer defined - necessary when multiple components or systems are present on the vehicle and have the same definition of test ID. |
||||