Engine Control Module (ECM) Replacement: Notes
- Using a scan tool, retrieve the percentage of remaining engine oil. Record the remaining engine oil life.
- Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure in Engine Electrical.
- Disconnect the intake air temperature (IAT) sensor.
- Loosen the clamp at the air cleaner assembly.
- Remove the push pin attachment from the outlet resonator/duct assembly to support bracket.
- Loosen the clamp at the throttle body assembly.
- Disconnect the PCV fresh air hose at the cam cover.
- Remove the outlet resonator/duct assembly.
- Remove the J 1 and J 2 connectors at the ECM.
- Remove the 4 ECM attachment bolts.
IMPORTANT:
It is necessary to record the remaining engine oil life. If the replacement module is not programed with the remaining engine oil life, the engine oil life will default to 100%. If the replacement module is not programmed with the remaining engine oil life, the engine oil will need to be changed at 5000 km (3,000 mi) from the last engine oil change.