Scan Tool Data Definitions
- A/C Disengage Reason
-
The scan tool displays one of the following reasons why the PCM has disengaged the a/c compressor; None, System Voltage, WOT, CKP, Learn Active, Engine Run Time, Coolant Hot, Anti Stall, A/C Pressure, Engine Speed, Trans Engine Speed, A/C Pressure Sensor, Low Voltage, High Voltage, Outside Air, Temp, A/C Switched Off.
- A/C High Side Pressure Sensor
-
The scan tool displays 0-3450 kPa (0-500 psi). The voltage applied to the PCM input from the A/C refrigerant pressure sensor is converted to a pressure value. LX9 / 3.5L only.
- A/C High Side Pressure Sensor
-
The scan tool displays 0-5 volts. The voltage applied to the PCM input for the A/C refrigerant pressure sensor. LX9 / 3.5L only.
- A/C LED
-
The scan tool displays the On/Off status of the a/c request LED showing status of A/C engagement.
- A/C Off for WOT
-
The scan tool displays the high throttle disable of the a/c compressor.
- A/C Pressure Disable
-
The scan tool displays the status of the a/c high side pressure sensor. The scan tool displays Active/Inactive.
- A/C Relay Command
-
The scan tool displays On/Off. The scan tool displays the control decision for the compressor clutch relay output as determined by the PCM.
- A/C Relay Circuit History
-
The scan tool displays the following message stating the history status of the a/c relay control circuit. The scan tool displays OK/Open/Short.
- A/C Relay Circuit Status
-
The scan tool displays the following message stating the present status of the a/c relay control circuit. The scan tool displays OK/Fault.
- A/C Request Signal
-
The scan tool displays Yes/No. The scan tool displays Yes when the PCM receives a message to engage the A/C compressor clutch. The scan tool displays No when the PCM receives a message to disengage the A/C compressor clutch.
- A/C Request Switch
-
The scan tool displays On/Off. The a/c request switch shows current status of the a/c request switch function on the HVAC control module.
- Ambient Air Temperature Sensor
-
The scan tool displays -40 to 87.5°C (-40 to 189.5°F). The current value of the ambient air temperature sensor.
- Ambient Light Sensor
-
The scan tool displays 0-1023 counts (0-5.00 volts). The voltage applied to the ambient light sensor input of the BCM.
- A/C Switch
-
The scan tool displays the current status of the A/C switch engagement at the HVAC control head. The scan tool displays Active/Inactive.
- Auto Mode
-
The scan tool displays the current status of the A/C auto mode engagement at the HVAC control head. The scan tool displays On/Off.
- Battery Voltage Signal
-
The scan tool displays the level of battery voltage at the HVAC control module. The scan tool displays 0 - 12 V.
- Blower Motor Speed Command
-
The scan tool displays 0-100%. The scan tool displays the control decision for the blower motor speed as determined by the HVAC control module. The scan tool displays 100% when the blower motor is commanded to maximum speed. The scan tool displays 0% when the blower motor is commanded OFF.
- ECT Sensor
-
The scan tool displays -40 to 215°C (-40 to 419°F). The voltage applied to the PCM input from the engine coolant temperature sensor is converted to a temperature value.
- FC Relay 1 Command
-
The scan tool displays the command status of the PCM to relay 1. The scan tool displays On/Off. LX9 / 3.5L only.
- FC Relay 2 and 3 Command
-
The scan tool displays the command status of the PCM to relays 2 and 3. The scan tool displays On/Off. LX9 / 3.5L only.
- Ignition 1 Signal
-
The scan tool shows available voltage at the PCM. The scan tool displays 0-2 V.
- Inside Air Temp. Sensor
-
The scan tool displays -40 to 185°C (-40 to 365°F). The voltage applied to the HVAC control module input for the inside air temperature sensor is converted to a temperature value.
- Lower Duct Air Temp. Sensor
-
The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the HVAC control module from the lower duct air temperature sensor.
- Mode Dr. Position
-
The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the mode door position input of the HVAC control module.
- Mode Dr. Motor Commanded
-
The scan tool displays 0-255 counts (0-5.00 volts). The desired position of the mode actuator as determined by the HVAC control module.
- Mode Status
-
The scan tool displays the HVAC control module command of Def/Defog/Panel/Bi-level/Floor/Auto mode status.
- Outside Air LED
-
The scan tool displays the command status of the HVAC control module Outside Air switch LED. The scan tool displays On/Off.
- Outside Air Mode Switch
-
The scan tool displays the command status of the HVAC control module outside air mode switch. The scan tool displays On/Off.
- Recirculation LED
-
The scan tool displays the current status of the recirculation actuator LED. The scan tool displays On/Off.
- Recirculation Dr. Motor Command
-
The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the recirculation door command input of the HVAC control module.
- Recirculation Dr. Position
-
The scan tool displays 0-255 counts (0-5.00 volts). The desired position of the recirculation actuator as determined by the HVAC control module.
- Recirculation Switch
-
The scan tool displays the command status of the HVAC control module recirculation switch. The scan tool displays Active/Inactive.
- Sunload Sensor
-
The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the sunload input of the HVAC control module.
- Temp Dr. Motor Command
-
The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the air temperature door command input of the HVAC control module.
- Temp Dr. Motor Position
-
The scan tool displays 0-255 counts (0-5.00 volts). The desired position of the air temperature actuator as determined by the HVAC control module.
- Temp Down Switch
-
The scan tool displays the command status of the HVAC control module temperature switch. The scan tool displays Active/Inactive.
- Temp Up Switch
-
The scan tool displays the command status of the HVAC control module temperature switch. The scan tool displays Active/Inactive.
- Upper Duct Air Temp. Sensor
-
The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the HVAC control module from the upper duct air temperature sensor.