Scan Tool Data Definitions

WARNING: This page is about a different car, the 2005 Chevrolet Malibu. However, it is still accessible from the selected car via links, so may be relevant.
A/C Disengage Reason

The scan tool displays one of the following reasons why the PCM has disengaged the a/c compressor; None, System Voltage, WOT, CKP, Learn Active, Engine Run Time, Coolant Hot, Anti Stall, A/C Pressure, Engine Speed, Trans Engine Speed, A/C Pressure Sensor, Low Voltage, High Voltage, Outside Air, Temp, A/C Switched Off.

A/C High Side Pressure Sensor

The scan tool displays 0-3450 kPa (0-500 psi). The voltage applied to the PCM input from the A/C refrigerant pressure sensor is converted to a pressure value. LX9 / 3.5L only.

A/C High Side Pressure Sensor

The scan tool displays 0-5 volts. The voltage applied to the PCM input for the A/C refrigerant pressure sensor. LX9 / 3.5L only.

A/C LED

The scan tool displays the On/Off status of the a/c request LED showing status of A/C engagement.

A/C Off for WOT

The scan tool displays the high throttle disable of the a/c compressor.

A/C Pressure Disable

The scan tool displays the status of the a/c high side pressure sensor. The scan tool displays Active/Inactive.

A/C Relay Command

The scan tool displays On/Off. The scan tool displays the control decision for the compressor clutch relay output as determined by the PCM.

A/C Relay Circuit History

The scan tool displays the following message stating the history status of the a/c relay control circuit. The scan tool displays OK/Open/Short.

A/C Relay Circuit Status

The scan tool displays the following message stating the present status of the a/c relay control circuit. The scan tool displays OK/Fault.

A/C Request Signal

The scan tool displays Yes/No. The scan tool displays Yes when the PCM receives a message to engage the A/C compressor clutch. The scan tool displays No when the PCM receives a message to disengage the A/C compressor clutch.

A/C Request Switch

The scan tool displays On/Off. The a/c request switch shows current status of the a/c request switch function on the HVAC control module.

Ambient Air Temperature Sensor

The scan tool displays -40 to 87.5°C (-40 to 189.5°F). The current value of the ambient air temperature sensor.

Ambient Light Sensor

The scan tool displays 0-1023 counts (0-5.00 volts). The voltage applied to the ambient light sensor input of the BCM.

A/C Switch

The scan tool displays the current status of the A/C switch engagement at the HVAC control head. The scan tool displays Active/Inactive.

Auto Mode

The scan tool displays the current status of the A/C auto mode engagement at the HVAC control head. The scan tool displays On/Off.

Battery Voltage Signal

The scan tool displays the level of battery voltage at the HVAC control module. The scan tool displays 0 - 12 V.

Blower Motor Speed Command

The scan tool displays 0-100%. The scan tool displays the control decision for the blower motor speed as determined by the HVAC control module. The scan tool displays 100% when the blower motor is commanded to maximum speed. The scan tool displays 0% when the blower motor is commanded OFF.

ECT Sensor

The scan tool displays -40 to 215°C (-40 to 419°F). The voltage applied to the PCM input from the engine coolant temperature sensor is converted to a temperature value.

FC Relay 1 Command

The scan tool displays the command status of the PCM to relay 1. The scan tool displays On/Off. LX9 / 3.5L only.

FC Relay 2 and 3 Command

The scan tool displays the command status of the PCM to relays 2 and 3. The scan tool displays On/Off. LX9 / 3.5L only.

Ignition 1 Signal

The scan tool shows available voltage at the PCM. The scan tool displays 0-2 V.

Inside Air Temp. Sensor

The scan tool displays -40 to 185°C (-40 to 365°F). The voltage applied to the HVAC control module input for the inside air temperature sensor is converted to a temperature value.

Lower Duct Air Temp. Sensor

The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the HVAC control module from the lower duct air temperature sensor.

Mode Dr. Position

The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the mode door position input of the HVAC control module.

Mode Dr. Motor Commanded

The scan tool displays 0-255 counts (0-5.00 volts). The desired position of the mode actuator as determined by the HVAC control module.

Mode Status

The scan tool displays the HVAC control module command of Def/Defog/Panel/Bi-level/Floor/Auto mode status.

Outside Air LED

The scan tool displays the command status of the HVAC control module Outside Air switch LED. The scan tool displays On/Off.

Outside Air Mode Switch

The scan tool displays the command status of the HVAC control module outside air mode switch. The scan tool displays On/Off.

Recirculation LED

The scan tool displays the current status of the recirculation actuator LED. The scan tool displays On/Off.

Recirculation Dr. Motor Command

The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the recirculation door command input of the HVAC control module.

Recirculation Dr. Position

The scan tool displays 0-255 counts (0-5.00 volts). The desired position of the recirculation actuator as determined by the HVAC control module.

Recirculation Switch

The scan tool displays the command status of the HVAC control module recirculation switch. The scan tool displays Active/Inactive.

Sunload Sensor

The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the sunload input of the HVAC control module.

Temp Dr. Motor Command

The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the air temperature door command input of the HVAC control module.

Temp Dr. Motor Position

The scan tool displays 0-255 counts (0-5.00 volts). The desired position of the air temperature actuator as determined by the HVAC control module.

Temp Down Switch

The scan tool displays the command status of the HVAC control module temperature switch. The scan tool displays Active/Inactive.

Temp Up Switch

The scan tool displays the command status of the HVAC control module temperature switch. The scan tool displays Active/Inactive.

Upper Duct Air Temp. Sensor

The scan tool displays 0-255 counts (0-5.00 volts). The voltage applied to the HVAC control module from the upper duct air temperature sensor.