Circuit/System Testing
- Verify that DTC P0560 is set as current.
- Measure the voltage at the battery terminals and compare it with the scan tool ECM Ignition 1 signal parameter. Verify that battery and Ignition 1 signal readings do not differ more than 2.0 volts.
- If greater than the specified value, test the Ignition 1 and ground circuits of the ECM for an open/high resistance.
- Ignition 1 signal 2.0L X2 terminals 3 -5- 6 and X2 terminal 54.
- Ignition 1 signal 2.4L X1 terminals 19 - 20 and X2 terminal 13.
- Ground circuits 2.0L X2 terminals 1- 2 and 4.
- Ground circuit 2.4L X2 terminal 73.
- If the circuits test normal, replace the ECM.