Typical Scan Tool Data
ECT Sensor Temperature
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions:
Engine operating at various operating conditions Parameter Normal Range: -39 to +120°C (-38 to +248°F) |
||||
| ECT Sensor Signal | -39 to +120°C (-38 to +248°F) | 150°C (302°F) | -40°C (-40°F) | -40°C (-40°F) |
| Low Reference | - | - | -40°C (-40°F) | -40°C (-40°F) |