Circuit/System Testing
IMPORTANT:
- Larger volume fuel tanks and/or those with lower fuel levels may require several minutes for the floating indicator to stabilize.
- Refer to J 41413-200 (J 41413-100) operation manual for detailed instructions in Evaporative Emission System Diagnosis .
- Disconnect the purge tube at the quick connector on the EVAP canister side of the purge solenoid valve and install the CH-48096 . See Special Tools . Connect the J 41413-200 (J 41413-100) to the CH-48096 . See Special Tools .
- Use a scan tool to seal the system.
- Use the flow meter on the J 41413-200
(J 41413-100) calibrated to 0.51 mm (0.020 in) to determine that there is no leak in the EVAP system.
- If a leak is detected, use the J 41413-200 (J 41413-100) to apply smoke to the EVAP system at the service port or the filler neck until the leak is located.