Circuit/System Testing
WARNING: This page is about a different car, the 2008 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:
To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
- Disconnect the 3-phase cables from the SGCM. Refer to Generator Control Module 3-Phase Cable Assembly Replacement .
- Test each of the 3-phase cables individually for a short to ground.
- If any circuit indicates a short to ground, disconnect the 3-phase cables from the MGU.
- If the short to ground condition is longer present, replace the MGU.
- Test each of the 3-phase cables individually for a short to ground.
- If any circuit does not test normal, replace the 3-phase cable assembly.
- If all circuits test normal, replace the SGCM.