Shift Lock Control Switch (ATM): Inspection
WARNING: This page is about a different variant/trim than selected.
- INSPECT SHIFT LOCK CONTROL SWITCH
- Disconnect the connector of the shift lock control switch.
- Measure the resistance according to the value(s) in SHIFT LOCK CONTROL SWITCH (ATM) RESISTANCE SPECIFICATIONS (DISCONNECTED) .SHIFT LOCK CONTROL SWITCH (ATM) RESISTANCE SPECIFICATIONS (DISCONNECTED)
Terminal Measuring Condition Specified Value A5 (IG) - B2 (SLS+) Switch ON Below 1 Ω A5 (IG) - B2 (SLS+) Switch OFF 10 kΩ or higher If the result is not as specified, replace the shift lock control switch.
- Connect terminal STP to the battery positive (+) terminal and terminal E to the battery negative (-) terminal, and apply about 12 V between terminals STP and E.
- Measure the resistance according to the value(s) in SHIFT LOCK CONTROL SWITCH (ATM) RESISTANCE SPECIFICATION (CONNECTED) .
SHIFT LOCK CONTROL SWITCH (ATM) RESISTANCE SPECIFICATION (CONNECTED)Terminal Measuring Condition Specified Value A1 (E) - B1 (SLS-) Connect Battery Below 1 Ω A1 (E) - B1 (SLS-) Disconnect Battery 10 kΩ or higher If the result is not as specified, replace the shift lock control switch.