LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Scion >> 2005 >> xB Standard >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> Starting System & Charging System >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

Starting And Charging Service Data

Starter assy  
Specified current 90 A or less at 11.5V
Starter relay  
Specified condition 3 - 5 10 kΩ or higher
Below 1 Ω (Apply battery voltage to terminal 1 and 2)
Battery  
Except maintenance-free battery Standard specific gravity 1.27 to 1.29 at 20°C (68°F)
Voltage at 20°C (68°F) 12.5 to 12.9 V
Voltage regulator Regulating voltage 12.9 to 14.9 V
Standard amperage 10 A or less
Starter armature assy  
Commutator length Standard 3.1 mm (0.122 in.)
Minimum 3.8 mm (0.150 in.)
Starter commutator assy  
Brush length Standard 9.0 mm (0.354 in.)
Minimum 4.0 mm (0.158 in.)
Starter armature assy  
Snap ring length Maximum 5.0 mm (0.197 in.)
Generator rotor assy  
Coil resistance at 20°C (68°F) 2.1 to 2.5 Ω
Slip ring diameter Standard 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum 12.8 mm (0.504 in.)
Generator brush holder assy  
Exposed brush length Standard 9.5 to 11.5 mm (0.374 to 0.453 in.)