Heated Oxygen Sensor: Inspection
- INSPECT HEATED OXYGEN SENSOR
- Check the resistance.
- Using an ohmmeter, measure the resistance between the terminals.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 (HT1B) - 2 (+B) 20°C (68°F) 11 Ω to 16 Ω 1 (HT1B) - 4 (E2) - 10 kΩ or higher If the resistance is not as specified, replace the heated oxygen sensor.
- Using an ohmmeter, measure the resistance between the terminals.
- Check the resistance.