Service Data
| Thermostat | Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 10 mm (0.39 in.) or more at 95°C (203°F) | |
| Cooling fan motor | Standard current | 7.4 to 10.9 A at 20°C (68°F) |
| No. 2 cooling fan motor | Standard current | 5.7 to 7.7 A at 20°C (68°F) |
| No. 1 fan relay (FAN NO. 1) |
Standard resistance 3 - 5 |
10 Ω or higher (battery voltage not applied) |
| Below 1 Ω (battery voltage applied to terminal 1 and 2) | ||
| No. 2 fan relay (FAN NO. 2) |
Standard resistance 3 - 4 |
Below 1 Ω (battery voltage applied to terminal 1 and 2) |
| 10 Ω or higher (battery voltage not applied) | ||
| Standard resistance 3 - 5 |
10 Ω or higher (battery voltage not applied) | |
| Below 1 Ω (battery voltage applied to terminal 1 and 2) | ||
| No. 3 fan relay (FAN NO. 3) |
Standard resistance 3 - 5 |
10 Ω or higher (battery voltage not applied) |
| Below 1 Ω (battery voltage applied to terminal 1 and 2) | ||
| Radiator reservoir cap | Standard valve (for brand-new cap) |
93.3 to 122.7 kPa (0.95 to 1.3 kgf/cm2 , 13.5 to 17.8 psi) |
| Standard valve (for using cap) |