Typical Enabling Conditions
| Monitor runs whenever following DTCs not present | P0010 (OCV bank 1) P0011 (VVT system 1 - advance) P0012 (VVT system 1 -retard) P0016 (VVT system 1 - misalignment) P0102, P0103 (MAF meter) P0115 - P0118 (ECT sensor) P0120 - P2135 (Throttle position sensor) P0125 (Insufficient ECT for closed loop) P014C, P014D, P015A, P015B (A/F sensor) P0171, P0172 (Fuel system) P0301 - P0304 (Misfire) P0335 (Crankshaft position sensor) P0340 (Camshaft position sensor) P0351 - P0354 (Ignitor) P0500 (Vehicle speed sensor) P2195, P2196 (A/F sensor) P2237-P2253 (A/F sensor) |
| Battery voltage | 8 V or more |
| Time after engine start | 3 seconds or more |
| Starter | OFF |
| ECT at engine start | -10°C (14°F) or more |
| ECT | -10°C (14°F) or more, and less than 50°C (122°F) |
| Engine idling time | 3 seconds or more |
| Fuel-cut | OFF |
| Vehicle speed | Less than 3 km/h (1.875 mph) |
| Time after shift position changed | 1 second or more [AT] |
| Atmospheric pressure | 76 kPa (570 mmHg) or more |