Basic Power Window System Inspection [07/2015 - ]: Procedure
- CHECK POWER WINDOW SYSTEM INSPECTION
Result
Result Proceed to Manual Open/close Function Inspection A Auto Open/close Function (Driver-side) Inspection B IG-OFF Timer Function Inspection C Auto Reverse Pinch Protection Function Inspection D Result: 2
B
See step 5
Result: 3
C
See step 8
Result: 4
D
See step 13
Result: 1
A
See step 2
- SWITCH THE IGNITION ON (ENGINE OFF OR ON).
- Operate the power window using the manual open/close function on the power window master switch.
- Does the power window operate properly?
Result
Result Yes No
Result: 2
No
INSPECT THE POWER WINDOW MASTER SWITCH AND THE WIRING HARNESS.
- Repair or replace malfunctioning parts.
Result: 1
Yes
See step 3
- SET THE POWER CUT SWITCH TO THE UNLOCK (CONTACT POINT: CLOSE) POSITION.
- Operate the power window using the power window switch.
- Does the power window operate properly?
Result
Result Yes No
Result: 2
No
INSPECT THE POWER WINDOW SWITCH AND THE WIRING HARNESS.
- Repair or replace malfunctioning parts.
Result: 1
Yes
See step 4
- SET THE POWER CUT SWITCH TO THE LOCK (CONTACT POINT: OPEN) POSITION.
- Operate all power windows other than the driver side.
- Does the power window operate properly?
Result
Result Yes No
Result: 1
Yes
INSPECT THE POWER CUT SWITCH AND THE WIRING HARNESS
- Replace the power window master switch.
Result: 2
No
MANUAL OPEN/CLOSE FUNCTION IS NORMAL.
- Perform the auto open/close function inspection.
- SWITCH THE IGNITION ON (ENGINE OFF OR ON).
- Operate the power window using the auto open / close function on the power window master switch.
- Does the power window operate properly?
Result
Result Yes No
Result: 2
No
IF THE POWER WINDOW AUTOMATICALLY OPENS DURING THE CLOSING OPERATION:
- Go to DRIVER-SIDE DOOR GLASS REVERSE OPENS DURING AUTO-CLOSE (MANUAL CLOSE) OPERATION (MIS REVERSE OPEN) [POWER WINDOW SYSTEM].
Others:
- Go to DRIVER-SIDE DOOR GLASS CAN BE OPERATED MANUALLY BUT CANNOT BE OPERATED AUTOMATICALLY [POWER WINDOW SYSTEM].
Refer to DRIVER-SIDE DOOR GLASS CAN BE OPERATED MANUALLY BUT CANNOT BE OPERATED AUTOMATICALLY [07/2015 - ]
Result: 1
Yes
See step 6
- OPERATE THE POWER WINDOW MASTER SWITCH TO THE CLOSE POSITION WHILE THE POWER WINDOW IS OPENING.
Result: 2
No
REPLACE THE POWER WINDOW MASTER SWITCH (POWER WINDOW CONTROL UNIT IS MALFUNCTIONING.)
Result: 1
Yes
See step 7
- OPERATE THE POWER WINDOW MASTER SWITCH TO THE OPEN POSITION WHILE THE POWER WINDOW IS CLOSING.
Result: 1
Yes
AUTO OPEN/CLOSE FUNCTION IS NORMAL.
- Perform the IG-OFF timer function inspection.
Result: 2
No
REPLACE THE POWER WINDOW MASTER SWITCH (POWER WINDOW CONTROL UNIT IS MALFUNCTIONING.)
- CLOSE ALL DOORS.
- Switch the ignition from ON (engine off or on) to off.
- Operate the power window master switch within 40 s after switching the ignition to off.
- Does the power window operate?
Result
Result Yes No
Result: 2
No
See step 12
Result: 1
Yes
See step 9
- OPEN ANY DOOR.
- Switch the ignition from ON (engine off or on) to off.
- Operate the power window master switch within 40 s after switching the ignition to off.
- Does the power window operate?
Result
Result Yes No
Result: 2
Yes
See step 11
Result: 1
No
See step 10
- CLOSE ALL DOORS.
- Switch the ignition from ON (engine off or on) to off.
- Operate the power window master switch within 60 s after switching the ignition to off.
- Does the power window operate?
Result
Result Yes No
Result: 1
Yes
REPLACE THE POWER WINDOW MASTER SWITCH (POWER WINDOW CONTROL UNIT IS MALFUNCTIONING.)
Result: 2
No
IG-OFF TIMER FUNCTION OPERATION IS NORMAL.
- Perform the auto reverse pinch protection function inspection.
- INSPECT THE DOOR SWITCHES AND RELATED WIRING HARNESS.
- If above parts are okay, replace the power window master switch, then go to the next step.
- If above parts are incorrect repair or replace malfunction part (s), then go to the next step.
Result
Proceed to NEXT
Result: 1
NEXT
See step 10
- INSPECT THE DOOR SWITCHES AND RELATED WIRING HARNESS.
- If above parts are okay, replace the power window master switch, then go to the next step.
- If above parts are incorrect repair or replace malfunction part (s), then go to the next step.
Result
Proceed to NEXT
Result: 1
NEXT
See step 9
- SWITCH THE IGNITION ON (ENGINE OFF OR ON).
- Fully open the driver-side power window.
- Set the hammer (thickness: 10 mm {0.39 in} or more) as shown below. Then, close the power window.
- Verify that the power window opens approx. 200 mm {2.87 in} after contacting the hammer and the operation stops.
- Does auto reverse pinch protection function operate properly?
Result
Result Yes No
Result: 2
Yes
AUTO REVERSE PINCH PROTECTION FUNCTION IS NORMAL.
Result: 1
No
See step 14
- DOES POWER WINDOW OPEN BEFORE CONTACTING THE HAMMER?
Result
Result Yes No Result: 1
Yes
GO TO DRIVER-SIDE DOOR GLASS REVERSE OPENS DURING AUTO-CLOSE (MANUAL-CLOSE) OPERATION (MIS REVERSE OPEN) [POWER WINDOW SYSTEM].
Result: 2
No
INITIALIZE THE POWER WINDOW MASTER SWITCH.
HINT:
- Before initializing the power window master switch, cut off the power supply to the power window master switch for approx. 60 s. Then, reconnect it again after approx. 60 s:
- Disconnect the negative battery cable.
- Disconnect the power window master switch connector.
- Remove the fuse for the power window system.
- Before initializing the power window master switch, cut off the power supply to the power window master switch for approx. 60 s. Then, reconnect it again after approx. 60 s: