Test 4: Outlet Solenoid Valve Circuit Problem
- Turn ignition off. Disconnect ABS hydraulic unit harness connector. Measure resistance between hydraulic unit terminals. See CHECKING SOLENOID VALVE CIRCUIT RESISTANCE table. See Figure
. Resistance should be about 3-5 ohms. If resistance is as specified, go to next step. If resistance is not as specified, replace hydraulic unit.CHECKING SOLENOID VALVE CIRCUIT RESISTANCE
DTC Terminals No. 32 7 & 9 34 8 & 10 36 5 & 10 38 6 & 9 - Measure resistance between ground and terminal at hydraulic unit. See CHECKING SOLENOID VALVE FOR SHORT table. See Figure
. Resistance should be infinite. If resistance is as specified, go to next step. If resistance is not as specified, replace hydraulic unit.CHECKING SOLENOID VALVE FOR SHORT
DTC Terminals No. 32 7 34 8 36 5 38 6 - Disconnect ABS/TCS control unit connectors. Measure resistance between ground and terminal at ABS/TCS control unit harness connector. See ABS/TCS CONTROL UNIT CIRCUITS table. If resistance is infinite, go to next step. If resistance is not infinite, repair wiring harness as necessary.ABS/TCS CONTROL UNIT CIRCUITS
DTC Terminals No. 32 (1) 3 34 (2) 1 36 (2) 3 38 (1) 8 (1) Terminals are located in ABS/TCS control unit 8-pin harness connector. (2) Terminals are located in ABS/TCS control unit 6-pin harness connector. - Reconnect hydraulic unit connector. Ensure ABS/TCS connectors are disconnected. Measure resistance between terminal No. 6 at ABS/TCS connector 16-pin connector and ABS/TCS control unit 6-pin and 8-pin connectors as specified. See ABS/TCS CONTROL UNIT CIRCUITS . See Figure . If resistance is 5-7 ohms, replace ABS/TCS control unit. If resistance is not 5-7 ohms, repair wiring harness as necessary.