Abs Sequence Control With SUBARU Select Monitor
NOTE:
- In the event of any trouble, the sequence control may not be operative. In such a case, activate the sequence control, referring to ABS SEQUENCE CONTROL WITH DIAGNOSIS CONNECTOR , ABS Sequence Control .
- When the diagnosis terminal is connected to the diagnosis connector, the sequence control will not operate.
- Connect the Subaru Select Monitor to data link connector under driver's seat instrument panel lower cover.
- Turn the ignition switch to ON.
- Turn the Subaru Select Monitor switch to ON.
- Put the Subaru Select Monitor to "BRAKE CONTROL" mode.
- When "Function check sequence" is selected, 'ABS sequence control' will start.
- When the message "Press Brake Pedal Firmly" is displayed, perform the followings.
- When using the brake tester, depress the brake pedal with braking force of 981 N (100 kgf, 221 lb).
- When using the pressure gauge, depress the brake pedal so as to make the pressure gauge indicate 3,432 kPa (35 kg/cm2 , 498 psi).
CAUTION: Do not depress the clutch pedal in case of vehicle with hill holder. - When the message "Press YES" is displayed, press the YES key.
- The braking system in operation is displayed on Subaru Select Monitor.