Check Security Indicator Light Circuit
CHECKING STEPS REFERENCE
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK SECURITY INDICATOR LIGHT.
|
Does the security indicator light illuminate? | Replace the security control module. | Go to step 2. |
2 CHECK POWER SUPPLY FOR SECURITY INDICATOR LIGHT.
|
Is the measured value more than 10 V? | Go to step 3. | Check the harness for open circuits and shorts between the combination meter and the fuse. |
| 3 CHECK SECURITY INDICATOR LIGHT CIRCUIT. Measure the resistance between the combination meter harness connector terminal and security control module harness connector terminal. Connector & terminal
|
Is the measured value less than 10Ω? | Replace the combination meter printed circuit. | Check the harness for open circuits and shorts between the combination meter and security control module. |