Abs Sequence Control With SUBARU Select Monitor
NOTE:
- In the event of any trouble, the sequence control may not be operative. In such a case, activate the sequence control, referring to "ABS SEQUENCE CONTROL WITH DIAGNOSIS CONNECTOR".
< Ref. to ABS SEQUENCE CONTROL WITH DIAGNOSIS CONNECTOR <-- , ABS Sequence Control -->.>
- When the diagnosis terminal is connected to the diagnosis connector, the sequence control will not operate.
- Connect the Subaru Select Monitor to data link connector under driver's seat instrument panel lower cover.
- Turn the ignition switch to ON.
- Turn the Subaru Select Monitor switch to ON.
- Put the Subaru Select Monitor to "BRAKE CONTROL" mode.
- When "Function check sequence" is selected, 'ABS sequence control' will start.
- When the message "Press Brake Pedal Firmly" is displayed, perform the followings.
- When using the brake tester, depress the brake pedal with braking force of 1,000 N (102 kgf, 225 lb).
- When using the pressure gauge, depress the brake pedal so as to make the pressure gauge indicate 3,500 kPa (36 kg/cm2 , 511 psi).
- When the message "Press YES" is displayed, press the YES key.
- The braking system in operation is displayed on Subaru Select Monitor.