Check Hazard Light Operation
HAZARD LIGHT OPERATION
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK HAZARD LIGHT OPERATION. Make sure the hazard light blinks when hazard switch is turned ON. |
Does the hazard light blink? | Go to step 2. | Check the hazard light circuit. |
2 CHECK OUTPUT SIGNAL.
Connector & terminal (B176) No. 12, 18 (+) - Chassis ground (-): |