Electrical Specification
INPUT OUTPUT SIGNAL SPECIFICATIONS
| Contents | To Connector No. | Terminal No. | Input/Output signal |
|---|---|---|---|
| Measured value and measuring conditions | |||
| Battery power supply | B281 | 2 | 9 - 16 V |
| Ignition power supply | B280 | 19 | 10 - 15 V when ignition switch is at ON or START. |
| ACC power supply | B280 | 10 | 10 - 15 V when ignition switch is at ACC or ON. |
| Inhibitor Switch ("P" position) | B280 | 5 | 0 V when select lever is in "P" position. 9 - 16 V when select lever is in other positions than "P" position. |
| Stop light switch | B280 | 9 | 9 - 16 V when stop light switch is ON. 0 V when stop light switch is OFF. |
| "P" position switch | B280 | 6 | 0 V when select lever is in "P" position. 9 - 16 V when select lever is in other positions than "P" position. |
| Shift lock solenoid signal | B281 | 9 | 8.5 - 16 V when shift lock is released. 0 V when shift lock is operating. |
| Key warning switch signal | B280 | 20 | 9 - 16 V when key is inserted. 0 V when key is removed. |
| Key lock solenoid signal | B281 | 3 | Pulse is output when switching key lock between locked and unlocked. 0 V at other conditions than above. |
| Ground | B281 | 4 | - |
| Ground | B281 | 13 | - |