VDC Hydraulic Control Module (VDCH/M): Inspection: Notes
- Check the connection and fixture of the connector.
- Inspect the valve relay and motor relay for broken wires or short circuits.
- Inspect the identification of the VDCH/M.
Refer to "SPECIFICATION " for the identification mark. <Ref. to SPECIFICATION General Description. >
RESISTANCE SPECIFICATION CHART
| Condition | Terminal No. | Standard | ||
|---|---|---|---|---|
| Valve relay | When not applying voltage | 85 - 86 | 103±10 Ω | |
| 30 - 87a | Less than 0.5 Ω | |||
| 30 - 87 | 1 MΩ or more | |||
| When voltage (DC 12 V) is applied between terminal numbers 85 and 86. | 30 - 87a | 1 MΩ or more | ||
| 30 - 87 | Less than 0.5 Ω | |||
| Motor relay | When not applying voltage | 85 - 86 | 80±10 Ω | |
| 30 - 87 | 1 MΩ or more | |||
| When voltage (DC 12 V) is applied between terminal numbers 85 and 86. | 30 - 87 | Less than 0.5 Ω |