VDC Hydraulic Control Module (VDCH/M): Installation: VDCH/M
- Install the VDCH/M.
Tightening torque: 18 N.m (1.8 kgf-m, 13.0 ft-lb)
- Secure the grounding wire of the VDCH/M and apply the specified grease to the ground terminals.
Specified grease: Nippeco LT or GB
Tightening torque: 33 N.m (3.3 kgf-m, 23.9 ft-lb)
- Connect brake pipes to the VDCH/M connectors.
Tightening torque: 15 N.m (1.5 kgf-m, 10.8 ft-lb)
- Fasten the VDCH/M connector to the connector bracket.CAUTION: Match the connector to the corresponding socket.
- Connect the connector to VDCH/M.
- Install the air intake duct.
- Connect the ground cable to the battery.
- Bleed air from the brake system.