VDC Hydraulic Control Module (VDCH/M): Inspection: Notes
- Check the connection and fixture of the connector.
- Inspect the valve relay and motor relay for broken wires or short circuits.
- Inspect the identification of the VDCH/M. Refer to "SPECIFICATION" for the identification mark. < Ref. to
SPECIFICATION , General Description.>STANDARD VALUE SPECIFICATION
Condition Terminal No. Standard value Valve relay When not applying voltage 85 - 86 103 ± 10 Ω 30 - 87a Less than 0.5 Ω 30 - 87 1 MΩ or more When voltage (DC 12 V) is applied between terminal numbers 85 and 86. 30 - 87a 1 MΩ or more 30 - 87 Less than 0.5 Ω Motor relay When not applying voltage 85 - 86 80 ± 10 Ω 30 - 87 1 MΩ or more Motor relay When voltage (DC 12 V) is applied between terminal numbers 85 and 86. 30 - 87 Less than 0.5 Ω