VDC Control Module and Hydraulic Control Unit (VDCCM&H/U): Installation
- Install the VDCCM&H/U bracket.
Tightening torque:
33 N.m (3.3 kgf-m, 24 ft-lb)
- Install the VDCCM&H/U to the bracket.
Tightening torque:
7.5 N.m (0.76 kgf-m, 5.5 ft-lb)
CAUTION: Attach so that the protrusion of the stud bolt is at the position shown in the figure. - Connect the brake pipes to their correct VDCCM&H/U positions.
Tightening torque:
< Ref. to FRONT BRAKE PIPES AND HOSE , COMPONENT, General Description . >
- Connect the VDCCM&H/U connector.NOTE:
- Be sure to remove all foreign matter from inside the connector before connecting.
- Make sure the VDCCM&H/U connector is securely locked.
- Bleed air from the brake system.