SUBARU Select Monitor (Normal Mode)

  1. On the «Main Menu» display screen, select the {Each System Check}.
  2. On the «System Selection Menu» display screen, select the {Engine Control System}.
  3. Click the [OK] button after the information of engine type has been displayed.
  4. On the «Engine Diagnosis» display screen, select the {Clearing Memory}.
  5. When the "Clear Memory?" is shown on the screen, click the [Yes] button.
  6. When "Done" and "Turn off the ignition switch" are shown on the display screen, turn the ignition switch to OFF.
    NOTE:
    • Initial diagnosis of electronic throttle control is performed after memory clearance. Wait for 10 seconds or more after turning the ignition switch to ON, and then start the engine.
    • For detailed operation procedures, refer to the "SUBARU SELECT MONITOR ".