Non-Turbo Model

NON-TURBO MODEL SPECIFICATION CHART

Item Specification
Starter Type Reduction type
Vehicle model MT AT
Model M000T30475 M000T20175
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 1.0 kW 12 V - 1.4 kW
Direction of rotation Counterclockwise (when observed from pinion)
Number of pinion teeth 8 9
No-load characteristics Voltage 11 V
Current 95 A or less 90 A or less
Rotating speed 2,500 RPM or more 2,000 RPM or more
Load characteristics Voltage 7.5 V 7.7 V
Current 300 A 400 A
Torque 8.84 N.m (0.9 kgf-m, 6.5 ft-lb) or more 16.7 N.m (1.7 kgf-m, 12.3 ft-lb) or more
Rotating speed 870 RPM or more 710 RPM or more
Lock characteristics Voltage 4V 3.5 V
Current 680 A or less 960 A or less
Torque 17 N.m (1.7 kgf-m, 12.5 ft-lb) or more 31 N.m (3.2 kgf-m, 22.9 ft-lb) or more
Generator Type Rotating-field three-phase type, voltage regulator built-in type, with load response control system
Model A2TG0391
Manufacturer Mitsubishi Electric
Voltage and output 12V - 90A
Polarity on ground side Negative
Direction of rotation Clockwise (when observed from pulley side)
Armature connection 3-phase Y-type
Output current 1,500 RPM - 40 A or more
2,500 RPM - 74 A or more
5,000 RPM - 84 A or more
Regulated voltage 14.1-14.8 V [20°C(68°F)]
Battery Type and capacity 12 V - 48AH(55D23L) 12 V - 52AH(75D23L)