Diagnostic Method
- Exhaust temperature diagnosis
Abnormality Judgment
When the diagnostic execution conditions are established, calculate the estimated exhaust temperature. Judge as NG when the following conditions are established after engine starting within the predetermined time.
Judgment Value
| Malfunction Criteria | Threshold Value |
|---|---|
| Estimated exhaust gas temperature | < Value from Map |
Map
| Coolant temperature after starting the engine | -30 °C (-22 °F) | -20 °C (-4°F) | -10 °C (14 °F) | 0°C (32 °F) | 10 °C (50 °F) | 20 °C (68 °F) | 30 °C (86 °F) | 40 °C (104 °F) | 50 °C (122 °F) | 60 °C (140 °F) |
| Estimated exhaust gas temperature | 200 °C (392 °F) | 200 °C (392 °F) | 200 °C (392 °F) | 225 °C (437 °F) | 225 °C (437 °F) | 220 °C (428 °F) | 210 °C (410 °F) | 200 °C (392 °F) | 190°C (374 °F) | 190 °C (374 °F) |
Time Needed for Diagnosis: 14 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
Judgment Value
| Malfunction Criteria | Threshold Value |
|---|---|
| Estimated exhaust gas temperature | ≥ Value from Map |
Time Needed for Diagnosis: Less than 1 second
- Idle speed diagnosis
Abnormality Judgment
Judge as NG when the following conditions are established after the predetermined time.
Judgment Value
| Malfunction Criteria | Threshold Value |
|---|---|
| Continuous time of (Target engine speed - Actual engine speed > -200 RPM) | ≥ 6000 ms |
| Continuous time of (actual retard amount > 20 °CA) | ≥ 0 ms |
Time Needed for Diagnosis: 14 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
Judgment Value
| Malfunction Criteria | Threshold Value |
|---|---|
| Continuous time of (Target engine speed - Actual engine speed > -200 RPM) | < 6000 ms |
| Continuous time of (actual retard amount > 20 °CA) | < 0 ms |
Time Needed for Diagnosis: Less than 1 second
- Final ignition timing diagnosis
Abnormality Judgment
Judge as NG when the following conditions are established with diagnosis enable conditions successful.
Judgment Value
| Malfunction Criteria | Threshold Value |
|---|---|
| Continuous time of (Standard ignition timing - Actual ignition timing ≤ 0 °CA) | > 5000 ms |
Time Needed for Diagnosis: 5000 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
Judgment Value
| Malfunction Criteria | Threshold Value |
|---|---|
| Continuous time of (Standard ignition timing - Actual ignition timing > 0 °CA) | > 1000 ms |
Time Needed for Diagnosis: 1000 ms