Fuel Pump Control (On/Off Drive)
CAUTION:
After executing the system operation check mode, execute the Clear Memory Mode. < refer to
OPERATION , Clear Memory Mode >
- On << System Operation Check Mode >> display, select {Fuel Pump Control}.
- On << Fuel Pump Control >> display, select {ON/OFF Dr.}.
- On << Turn Ignition Switch ON with Engine OFF >> display, turn the ignition switch to ON and click the [OK] button.
- On << ON/OFF Dr. >> display, click the [Execution] button and execute the ON/OFF drive.
- Click the [Cancel] button to stop the ON/OFF drive.
- Click the [[F12] Exit] button to end the ON/OFF drive. The screen will return to the << Fuel Pump Control >> screen.NOTE: For detailed operation procedures, refer to application help for Subaru Select Monitor.