Enable Conditions
ENABLE CONDITION REFERENCE CHART
| Secondary Parameters | Enable Conditions |
| Battery voltage Closed loop control with main feedback Front oxygen (A/F) sensor impedance Elapsed time after starting the engine Engine coolant temperature Engine speed Amount of intake air After fuel cut Learning value of EVAP conc. during purge Total time of operating canister purge Engine load change Idle switch |
> 10.9 V Operation ≥ 0 Ω and < 50 Ω ≥ 40000 ms ≥ 0 C° (32 F°) ≥ 1000 rpm ≥ 10 g/s (0.35 oz/s) ≥ 3000 ms < 0.2 ≥ 20 s < 0.02 g/rev (0 oz/rev) OFF |