Non-Turbo Model

  1. Remove the V-belt covers.
    Fig 1: Locating V-Belt Covers Bolts
    G07665154Courtesy of SUBARU OF AMERICA, INC.
  2. Disconnect the ground cable from battery.
    Fig 2: Connecting/Disconnecting Battery Ground Terminal
    G08570271Courtesy of SUBARU OF AMERICA, INC.
  3. Remove the V-belts. < Refer to REMOVAL , V-belt. >
  4. Remove the V-belt cover bracket.
    Fig 3: Locating V-Belt Cover Bracket Bolts
    G07665156Courtesy of SUBARU OF AMERICA, INC.
  5. Disconnect the connector (A) and terminal (B) from the generator.
    Fig 4: Identifying Generator Connector And Terminal
    G07665157Courtesy of SUBARU OF AMERICA, INC.
  6. Remove the idler pulley from the chain cover.
    Fig 5: Locating Idler Pulley
    G07665158Courtesy of SUBARU OF AMERICA, INC.
  7. Remove the generator from the bracket.
    Fig 6: Locating Generator Mounting Bolts
    G07665159Courtesy of SUBARU OF AMERICA, INC.
  8. Remove the generator bracket from the generator.
    Fig 7: Locating Generator Bracket Mounting Bolt