Initialization Procedures
NOTE:
- Initialize the records inside the module by performing all the following steps regardless the item order.
- With each seat locked*, operating switches for 3 seconds make the buzzer sound once.
- If initialization is done after completing all items, the buzzer sounds three times when the last operation is completed and the switch is turned on then off.
- Move the seat rearward using the slide switch, and keep the seat lock* status for three seconds or more.
- Move the seat downward using tilt switch, and keep the seat lock* status for three seconds or more.
- Move the seat downward using lifter switch, and keep the seat lock* status for three seconds or more.
- Move the seat forward using reclining switch, and keep the seat lock* status for three seconds or more.
*: Seat lock is the status that there is no pulse output from the encoder within the specified period of time although it reaches the movable position end.
NOTE:
When the following conditions are met, the initializing operation is cancelled even though the procedure is carried out halfway.
- Interval between each initialization procedure of 1) to 4) exceeds 10 seconds.
- If any of initialization procedures 1) to 4) are not performed.
- The battery runs out or the voltage to the power seat control module falls out of the operation range during initialization.