| Main power supply |
VB (CONTROL 1) VB (CONTROL 2) |
C1 D7 |
- Battery voltage is detected when the main power is turned ON.
- "0 V" is detected when the main power is turned OFF.
|
| Command switch |
C12 |
- "0 V" is detected when the command switch is in CANCEL position.
- "Approx. 1 V" is detected when the command switch is in SET/COAST position.
- "Approx. 3 V" is detected when the command switch is in RESUME/ACCEL position.
- "Approx. 4 V" is detected when the command switch is released.
|
| Brake switch 1 (Brake switch) |
C15 |
- Battery voltage is detected when the brake pedal is released.
- "0 V" is detected when brake pedal is depressed.
|
| Brake switch 2 (Stop light switch) |
C3 |
- Battery voltage is detected when brake pedal is depressed.
- "0 V" is detected when the brake pedal is released.
|
| Main switch |
C13 |
- "0 V" is detected while the main switch is pressed or turned ON.
- "5 V" is present when the main switch is OFF.
|
| Ground |
GND (CONTROL) |
A6 |
- |
| Ignition switch |
C30 |
- Battery voltage is detected when the ignition switch is turned ON.
- "0 V" is detected when the ignition switch is turned OFF.
|
| Neutral signal |
C35 |
- Battery voltage is detected when the shift lever is in any position except for "P" or "N".
- "0 V" is detected when the shift lever is in "P" or "N" position.
|