Failsafe List
- Power window fail safeNOTE: If any malfunction occurs on the pulse sensor in the power window regulator motor assembly RH (driver's seat) and the power window regulator motor assembly LH (passenger's seat), the fail safe function is triggered.
- If any malfunction occurs on the pulse sensor for the auto-reverse function trigger, or any irregularity exists on window position or learned value, the following power window operations are prohibited.POWER WINDOW REGULATOR MASTER SWITCH assembly
Power window operation Conditions IG ON IG OFF Under permission of after-key-OFF operation IG OFF Under prohibition of after-key-OFF operation Manual UP (operating switch of own seat) x x - Manual DOWN (operating switch of own seat) ◦ x - During AUTO UP HOLD (operating switch of own seat) ◦(1) x - AUTO UP (operating switch of own seat) x x - AUTO DOWN (operating switch of own seat) x x - Manual UP (remote operation) x x - Manual DOWN (remote operation) x x - During AUTO UP HOLD (remote operation) x x - AUTO UP (remote operation) x x - AUTO DOWN (remote operation) x x - ◦: Operation permitted
x: Operation prohibited(1) Operating manual UP with AUTO UP HOLD (auto-reverse function is not activated) POWER WINDOW REGULATOR SWITCH assemblyPower window operation Conditions IG ON IG OFF Under permission of after-key-OFF operation IG OFF Under prohibition of after-key-OFF operation Manual UP (operating switch of own seat) x x - Manual DOWN (operating switch of own seat) ◦ x - During AUTO UP HOLD (operating switch of own seat) ◦(1) x - AUTO UP (operating switch of own seat) x x - AUTO DOWN (operating switch of own seat) x x - ◦: Operation permitted
x: Operation prohibited(1) Operating manual UP with AUTO UP HOLD (auto-reverse function is not activated) If pulse sensor is normal, fully close the window with manual operation (AUTO UP HOLD), and keep this operation for 1 second or more. This will cancel the fail safe and enable the AUTO operation.
- SW knob indicator controlNOTE: In normal operation (the fail safe is not active), knob indicator illuminates as shown in the diagram.
- Driver's seat
- Passenger's seat
- SW knob indicator control
- Initial failureNOTE: If window position or initialization finished status is failed to be read normally from the EEPROM, the following power window operations are prohibited.POWER WINDOW REGULATOR MASTER SWITCH assembly
Power window operation Conditions IG ON IG OFF Under permission of after-key-OFF operation IG OFF Under prohibition of after-key-OFF operation Manual UP (operating switch of own seat) x x - Manual DOWN (operating switch of own seat) ◦ x - During AUTO UP HOLD (operating switch of own seat) ◦(1) x - AUTO UP (operating switch of own seat) x x - AUTO DOWN (operating switch of own seat) x x - Manual UP (remote operation) x x - Manual DOWN (remote operation) x x - During AUTO UP HOLD (remote operation) x x - AUTO UP (remote operation) x x - AUTO DOWN (remote operation) x x - ◦: Operation permitted
x: Operation prohibited(1) Operating manual UP with AUTO UP HOLD (auto-reverse function is not activated) POWER WINDOW REGULATOR SWITCH assemblyPower window operation Conditions IG ON IG OFF Under permission of after-key-OFF operation IG OFF Under prohibition of after-key-OFF operation Manual UP (operating switch of own seat) x x - Manual DOWN (operating switch of own seat) ◦ x - During AUTO UP HOLD (operating switch of own seat) ◦(1) x - AUTO UP (operating switch of own seat) x x - AUTO DOWN (operating switch of own seat) x x - ◦: Operation permitted
x: Operation prohibited(1) Operating manual UP with AUTO UP HOLD (auto-reverse function is not activated) - SW knob indicator controlNOTE: During the initialization, if fail safe mode is activated because window position or initialization finished status is failed to be read normally from the EEPROM, SW knob indicator illuminates as shown in the diagram.
- Driver's seat:
Courtesy of SUBARU OF AMERICA, INC.
NOTE: When LIN communication is failed, the indicator blinks in a pattern of 1.4 seconds ON/1.4 seconds OFF. When LIN failure and other failure occurs simultaneously, the pattern of 0.7 seconds ON/0.7 seconds OFF is performed. - Passenger's seat
- Driver's seat:
- SW knob indicator control
- If LIN communication has any abnormality (communication fail), the power window operates as follows.POWER WINDOW REGULATOR MASTER SWITCH assembly
Power window operation IG ON Manual UP ◦(1) Manual DOWN ◦ During AUTO UP HOLD ◦(1) AUTO UP ◦(1) AUTO DOWN ◦ ◦: Operation permitted
x: Operation prohibited(1) With auto-reverse function enabled
Does not operate remotely.POWER WINDOW REGULATOR SWITCH assemblyPower window operation IG ON Manual UP ◦(1) Manual DOWN ◦ During AUTO UP HOLD ◦(1) AUTO UP ◦(1) AUTO DOWN ◦ ◦: Operation permitted
x: Operation prohibited(1) With auto-reverse function enabled
Does not operate remotely. - If LIN communication abnormality and pulse irregularity are detected simultaneously, the power window operates as follows.POWER WINDOW REGULATOR MASTER SWITCH assembly
Power window operation Always Manual UP x Manual DOWN ◦ During AUTO UP HOLD ◦(1) AUTO UP x AUTO DOWN x ◦: Operation permitted
x: Operation prohibited(1) Operating manual UP with AUTO UP HOLD (auto-reverse function is not activated)
Own seat's SW operation: Because LIN communication is in failure, the status of the IG signal is unknown, therefore UP operation without auto-reverse function control is prohibited.
Remote SW operation: Inoperable because LIN communication is failed.POWER WINDOW REGULATOR SWITCH assemblyPower window operation Always Manual UP x Manual DOWN ◦ During AUTO UP HOLD ◦(1) AUTO UP x AUTO DOWN x ◦: Operation permitted
x: Operation prohibited(1) Operating manual UP with AUTO UP HOLD (auto-reverse function is not activated)
Own seat's SW operation: Because LIN communication is in failure, the status of the IG signal is unknown, therefore UP operation without auto-reverse function control is prohibited.
Remote SW operation: Inoperable because LIN communication is failed. - If LIN communication abnormality and opening direction dead band deviation or LIN communication and initial failure are detected simultaneously, the power window operates as follows.POWER WINDOW REGULATOR MASTER SWITCH assembly
Power window operation Always Manual UP x Manual DOWN ◦ During AUTO UP HOLD ◦(1) AUTO UP x AUTO DOWN x ◦: Operation permitted
x: Operation prohibited(1) Operating manual UP with AUTO UP HOLD (auto-reverse function is not activated)
Remote control switch operation: Inoperable because LIN communication is failed.
- If any malfunction occurs on the pulse sensor for the auto-reverse function trigger, or any irregularity exists on window position or learned value, the following power window operations are prohibited.