Starting System & Charging System (Except STI): Generator: Inspection: Diode
CAUTION:
There is the possibility of damaging the diodes if a mega-tester (used to measure high voltages) or a similar measuring instrument is used. Never use a mega tester or equivalent for this test.
- Check for continuity between the diode lead and terminal E or B. If continuity is not as shown in the table, replace the rectifier.
- At analog type tester
Tester lead Continuity -lead +lead E P1, P2, P3, P4, P5, P6 Yes B No P1, P2, P3, P4, P5, P6 E No B Yes - At digital type tester
| Tester lead | Continuity | |
|---|---|---|
| -lead | +lead | |
| E | P1, P2, P3, P4, P5, P6 | No |
| B | Yes | |
| P1, P2, P3, P4, P5, P6 | E | Yes |
| B | No | |