Check Hazard Light Operation
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK HAZARD LIGHT OPERATION. Make sure the hazard light blinks when hazard switch is turned to ON. |
Does the hazard light blink? | Go to step 2. | Check the hazard light circuit. |
| 2 CHECK BODY INTEGRATED UNIT SETTING. Display the data of «Abnormal warning lamp flashing setting» using Subaru Select Monitor.
NOTE:
For detailed operation procedures, refer to "Application help".
|
Is the setting ON? | Go to step 3. | Turn the setting to ON. |
| 3 CHECK CURRENT DATA. Display the data of «Hazard Output» using Subaru Select Monitor. |
Is output signal present when operating the transmitter LOCK/UNLOCK button? | Go to step 4. | Go to step 5. |
| 4 CHECK KEYLESS ENTRY OPERATION. Press the LOCK/UNLOCK button of the keyless transmitter. |
Does it operate properly? | Replace the body integrated unit. < Ref. to BODY INTEGRATED UNIT . > | Check keyless entry system. < Ref. to SYMPTOM CHART , INSPECTION, Keyless Entry System. > |
5 CHECK HAZARD LIGHT CIRCUIT.
|
Is harness normal? | Check body integrated unit. < Ref. to BASIC DIAGNOSTIC PROCEDURE . > | Repair or replace the harness. |